    [Product Introduction]

    The principle of DY-LDY cold mirror dew point meter is based on the physical definition of dew point, and it is an internationally recognized standard of humidity measurement.The cold mirror dew point meter has the characteristics of high precision, no drift, long life and good repeatability.

    The mirror of the cold mirror dew point meter has been gold-plated, and the photoelectric measuring chamber is made of materials with excellent corrosion resistance to ensure the accuracy of the measurement data and adapt to the harsh working conditions.

    Range of application

    As a standard instrument for humidity dew point detection, cold mirror dew point meter is widely used in metrology detection, scientific research, military aerospace, medicine, tobacco, industrial production and other fields.

    [Technical indicators]

    Technical index of dew point

    Technical index of dew point

    Measuring range: -20~+85℃@20℃

    Refrigeration temperature difference: 45℃@20℃

    Uncertainty: ±0.2℃

    Separation rate: 0.01℃

    Repeatability: ±0.05℃

    Technical temperature index

    Measuring range: -40~+90℃

    Measurement: PT100 Class B 1/3 DIN B four-wire system

    Uncertainty: ±0.1℃

    Separation rate: 0.01℃

    Repeatability: ±0.05℃

    Instrument Technical Indicators

    Operating environment of main machine: -25~+55℃, 0~95%RH

    Display unit: T ambient temperature, DP dew point temperature, RH relative humidity, SH wet air specific humidity, AH absolute humidity, etc.

    Output: Modbus RTU communication, USB communication

    Sensor cable: 1.5m

    Response time: Refrigeration speed ≤0.8℃/S + equalization time (usually 15s)

    Sampling flow rate: 0.1~ 1NL /min

    Power supply: 220ACV 50HZ

    Schematic diagram of cold mirror dew point meter

    DY-LDY Cold Mirror Dew Point Apparatus

    Operation and Maintenance

    Before starting the machine, please connect the power supply, dew point probe and temperature probe cable. After starting the machine, the initialization time will be about 5 minutes. After initialization, the measuring state will start.After use, directly turn off the power to health.

    Press the up and down key to switch display parameters, short press Enter to switch display parameters above, long press Enter to Enter the DBC function, automatically clean the mirror.

    Routine maintenance and precautions are as follows:

    DBC (Automatic Cleaning Function) mode should be set to automatic mode (Manual mode should be set under normal conditions) in the case of more dust.

    If contaminants are found in the mirror, distilled water or alcohol can be used to clean the surface of the mirror and optical lens to ensure the measurement accuracy.

    Turn off the power supply before cleaning.Clean and air dry before starting the machine.

    Main interface introduction

    Top Left Status

    The number represents the current refrigeration power percentage. When it reaches 100%, it indicates that the upper refrigeration capacity has been reached

    Cool: probe refrigeration,

    The probe is heating

    Blan: The dew point is in equilibrium

    DBC: Mirror cleaning in progress

    Below sidebar status

    Max: Record the upper limit measurement for this parameter

    MIN: Record the lower limit measurement value of this parameter

    Shows the units represented by abbreviations as follows

    T: Ambient temperature

    Dp: Dew point temperature

    Rh: Relative humidity

    SH: Wet air humidity unit g/kg g/kg

    AH: Absolute humidity unit g/m3 g/m3 m3

    IH: Wet air enthalpy J /g joules /g

    PW: Current water vapor pressure in air unit hPa

    DY-LDY Cold Mirror Dew Point Apparatus

    DY-LDY Cold Mirror Dew Point Apparatus

    DY-LDY Cold Mirror Dew Point Apparatus

    DY-LDY Cold Mirror Dew Point Apparatus 2020-12-6 This article was read 3311 Times
    Previous:PartnerNext:Partner

    Technical

    Contact us

    Taian Demei Electromechanical Equipment Co.,LTD.

    Address:No. 8, Hedong Road, Shengzhuang Town, Taishan District, Taian, Shandong,China (Mainland)

    Tel: +86-538-6518016 / 6518018

    Mobile: +86-186 5382 5886

    Whatsapp: +86-186 5382 5886   Skype: +86 186 5382 5886

    Contact: Grace   Email: grace@demeithermo.com

    Sales network

    Taian Demei Electromechanical Equipment Co.,LTD.                          Publicity